FluxPro UF-824 — Floor-Standing Refrigerated Centrifuge, 6 × 2,400 ml
The UF-824 is a refrigerated floor-standing centrifuge specifically designed for use in blood banks and transfusion facilities. With a maximum capacity of twelve 500 ml blood pouches per run, it enables efficient processing of large specimen volumes. The centrifuge reliably delivers excellent and reproducible sedimentation results thanks to its very smooth running. It is an efficient, high performance blood bank centrifuge. The high-performance refrigeration system can be adjusted precisely over a temperature range from -20°C to +40°C. The Rapid Temp quick cooling function allows the centrifuge chamber and accessories to be pre-cooled to a defined temperature, which is particularly important when working with pre-chilled blood pouches.
Design
- High-quality steel structure with a built-in steel explosion-proof protective inner sleeve, three layers of protection, safe and reliable. 304# stainless steel chamber are autoclave-able and resistant detergents and disinfection liquids.
- The rotor body is made of national aviation standard aluminum LC4, processed and shaped after forging treatment and A-level depth flaw detection treatment, and passed static balance test and dynamic balance test.
- Observations window on lid for speed calibration and noise measurement.
- Microprocessor control with carbon brushless large torque frequency conversion motor, maintenance-free, no dust pollution.
User friendly
- CFC free refrigeration system, double-cycle refrigeration, heating and cooling double-loop control, strong heat and cold exchange capacity, no environmental pollution, precise temperature control.
- Pre-cooling feature, Precise temperature control up to – 20°C.
- Programmable and storable, stores up to 30 programs and provides direct user access with one keystroke save. The stored parameter: combination remains in the memory even after the centrifugation has been switched off.
- Provides the 10 acceleration rates and 10 braking ramp, to effectively avoid secondary sedimentation, with better centrifugation effect.
Safety
- Produced according to international safety regulations (e.g. IEC 61010)
- Safety Electrical lid interlock,door can not open when rotor is running and machine won’t run when lid open and error code appears.
- Emergency lid-lock release when power failure(very useful in an unexpected power interruption).
- Gas hinge for lid drop protection.
| Specifications | |
| Model | FluxPro UF-824 |
| Type | Floor-Standing Refrigerated Centrifuge, 6 × 2,400 ml |
| Speed Range | 0-8000 rpm adjustable |
| Max Speed | 8000 rpm |
| Speed Accuracy | ±20r/min |
| Max Capacity | 6 × 2400 ml/12 pcs 500 ml blood bags |
| RCF Range | 0-14900 ×g adjustable |
| Max RCF | 14900 ×g |
| Timer | 1-99h59minutes adjustable |
| Display | LCD |
| Noise | 65 to 68 dB(A) |
| Acceleration / Deceleration Rates | 1-- 12 |
| Temperature Range | -20 °C to +40 °C |
| Temperature Accuracy | ±1 °C |
| Program Memory | 30 |
| Dimensions (L × W × H) | 1000×850×1180 mm(L×W×H) |
| Net Weight | 500 kg |
| Power Supply | AC220V,50Hz,30A |
| Matched Rotors | Swing Rotors |
| Certification | CE, ISO13485,ISO9001, SFDA |
| Rotors & Accessories | |
| NO.1 Angle Rotor | 6×1000ml · 8000r/min · 14900xg |
| NO.2 Swing Rotor | 6×2400ml · 4000r/min · 5330xg |
| NO.3 Swing Rotor | 6×2×1000ml · 4000r/min · 5800xg |
| Ordering | |
| Part Number | UF-824 |
| Lead Time | 4–6 weeks ARO |
Specifications as published by the manufacturer; subject to change without notice. Contact sales@blazeasia.com to confirm rotor configuration for your tubes and volumes.