Fixed UV-C fixtures for rooms, cabinets, conveyors, cold rooms and hoods. Surface-mounted, recessed ceiling and compact strip models. All 230 V.
UVF-S Surface-Mount Fixtures

Wall or ceiling fixtures with a polished reflector. Choose high output (H) for the most UV, instant start (I) for frequent switching, or cold cathode (C) for long lamp life and cold rooms. Size H × W: 95 × 127 mm (one lamp) or 95 × 143 mm (two lamps).
UVF-S1H — one lamp, high output
| Model | Fixture length (mm) | Power | UV-C output (254 nm) |
|---|---|---|---|
| UVF-S1H-490 | 489 | 58 W | 11.5 W |
| UVF-S1H-640 | 641 | 73.7 W | 17 W |
| UVF-S1H-790 | 794 | 92.2 W | 23 W |
| UVF-S1H-950 | 946 | 108 W | 28 W |
| UVF-S1H-1250 | 1251 | 158.4 W | 40 W |
| UVF-S1H-1660 | 1657 | 193 W | 54 W |
UVF-S2H — two lamps, high output
| Model | Fixture length (mm) | Power | UV-C output (254 nm) |
|---|---|---|---|
| UVF-S2H-490 | 489 | 116 W | 23 W |
| UVF-S2H-640 | 641 | 147.4 W | 34 W |
| UVF-S2H-790 | 794 | 184.3 W | 46 W |
| UVF-S2H-950 | 946 | 216 W | 56 W |
| UVF-S2H-1250 | 1251 | 316.8 W | 80 W |
| UVF-S2H-1660 | 1657 | 386 W | 108 W |
UVF-S1I — one lamp, instant start
| Model | Fixture length (mm) | Power | UV-C output (254 nm) |
|---|---|---|---|
| UVF-S1I-340 | 337 | 12 W | 3.1 W |
| UVF-S1I-490 | 489 | 22 W | 5.8 W |
| UVF-S1I-640 | 641 | 30.7 W | 8.5 W |
| UVF-S1I-790 | 794 | 38.4 W | 11.2 W |
| UVF-S1I-950 | 946 | 42.9 W | 13.8 W |
| UVF-S1I-1250 | 1251 | 66 W | 19.3 W |
| UVF-S1I-1660 | 1657 | 94 W | 25 W |
UVF-S2I — two lamps, instant start
| Model | Fixture length (mm) | Power | UV-C output (254 nm) |
|---|---|---|---|
| UVF-S2I-340 | 337 | 24 W | 6.2 W |
| UVF-S2I-490 | 489 | 44 W | 11.6 W |
| UVF-S2I-640 | 641 | 61.4 W | 17 W |
| UVF-S2I-790 | 794 | 76.8 W | 22.4 W |
| UVF-S2I-950 | 946 | 85.8 W | 27.6 W |
| UVF-S2I-1250 | 1251 | 132 W | 38.6 W |
| UVF-S2I-1660 | 1657 | 188 W | 50 W |
UVF-S1C — one lamp, cold cathode
| Model | Fixture length (mm) | Power | UV-C output (254 nm) |
|---|---|---|---|
| UVF-S1C-340 | 337 | 18.8 W | 1.4 W |
| UVF-S1C-490 | 489 | 26.3 W | 3.2 W |
| UVF-S1C-640 | 641 | 28.8 W | 5 W |
| UVF-S1C-950 | 946 | 35 W | 8.5 W |
| UVF-S1C-1250 | 1251 | 42.5 W | 11.2 W |
UVF-S2C — two lamps, cold cathode
| Model | Fixture length (mm) | Power | UV-C output (254 nm) |
|---|---|---|---|
| UVF-S2C-490 | 489 | 52.6 W | 6.4 W |
| UVF-S2C-640 | 641 | 57.6 W | 10 W |
| UVF-S2C-950 | 946 | 70 W | 17 W |
| UVF-S2C-1250 | 1251 | 85 W | 22.4 W |
UVF-R Recessed Ceiling Fixtures
Fit flush into the ceiling for a clean look in clinics, labs, kitchens and cleanrooms. Depth 127 mm; width 229 mm (one or two lamps) or 356 mm (four lamps). Standard (S) or high output (H).
UVF-R1S — one lamp, standard output
| Model | Fixture length (mm) | Power | UV-C output (254 nm) |
|---|---|---|---|
| UVF-R1S-310 | 305 | 12 W | 3.1 W |
| UVF-R1S-460 | 457 | 22 W | 5.8 W |
| UVF-R1S-610 | 610 | 30.7 W | 8.5 W |
| UVF-R1S-760 | 762 | 38.4 W | 11 W |
| UVF-R1S-910 | 914 | 42.9 W | 15 W |
| UVF-R1S-1220 | 1219 | 66 W | 21 W |
| UVF-R1S-1630 | 1626 | 94 W | 33 W |
UVF-R2S — two lamps, standard output
| Model | Fixture length (mm) | Power | UV-C output (254 nm) |
|---|---|---|---|
| UVF-R2S-310 | 305 | 24 W | 6.2 W |
| UVF-R2S-460 | 457 | 44 W | 11.6 W |
| UVF-R2S-610 | 610 | 61.4 W | 17 W |
| UVF-R2S-910 | 914 | 85.8 W | 30 W |
| UVF-R2S-1220 | 1219 | 132 W | 42 W |
| UVF-R2S-1630 | 1626 | 188 W | 66 W |
UVF-R4S — four lamps, standard output
| Model | Fixture length (mm) | Power | UV-C output (254 nm) |
|---|---|---|---|
| UVF-R4S-310 | 305 | 48 W | 12.4 W |
| UVF-R4S-460 | 457 | 88 W | 23.2 W |
| UVF-R4S-610 | 610 | 122.8 W | 34 W |
| UVF-R4S-760 | 762 | 153.6 W | 44 W |
| UVF-R4S-910 | 914 | 171.6 W | 60 W |
| UVF-R4S-1220 | 1219 | 264 W | 84 W |
| UVF-R4S-1630 | 1626 | 376 W | 132 W |
UVF-R1H — one lamp, high output
| Model | Fixture length (mm) | Power | UV-C output (254 nm) |
|---|---|---|---|
| UVF-R1H-460 | 457 | 58 W | 11.5 W |
| UVF-R1H-610 | 610 | 73.7 W | 17 W |
| UVF-R1H-760 | 762 | 92.2 W | 23 W |
| UVF-R1H-910 | 914 | 108 W | 28 W |
| UVF-R1H-1220 | 1219 | 158.4 W | 40 W |
| UVF-R1H-1630 | 1626 | 193 W | 54 W |
UVF-R2H — two lamps, high output
| Model | Fixture length (mm) | Power | UV-C output (254 nm) |
|---|---|---|---|
| UVF-R2H-460 | 457 | 116 W | 23 W |
| UVF-R2H-610 | 610 | 147.4 W | 34 W |
| UVF-R2H-760 | 762 | 184.3 W | 46 W |
| UVF-R2H-910 | 914 | 216 W | 56 W |
| UVF-R2H-1220 | 1219 | 316.8 W | 80 W |
| UVF-R2H-1630 | 1626 | 386 W | 108 W |
UVF-R4H — four lamps, high output
| Model | Fixture length (mm) | Power | UV-C output (254 nm) |
|---|---|---|---|
| UVF-R4H-460 | 457 | 232 W | 46 W |
| UVF-R4H-610 | 610 | 294.8 W | 68 W |
| UVF-R4H-760 | 762 | 366.6 W | 92 W |
| UVF-R4H-910 | 914 | 432 W | 112 W |
| UVF-R4H-1220 | 1219 | 633.6 W | 160 W |
| UVF-R4H-1630 | 1626 | 772 W | 216 W |
UVF-T Compact Strip Fixture
A slim fixture for cabinets, enclosures and equipment.
| Model | Size H × L × W (mm) | UV-C output |
|---|---|---|
| UVF-T500 | 89 × 495 × 67 | 5 W |
Fixtures switched on in occupied areas must be shielded or interlocked. Ask us about door switches, motion sensors and timers.
Typical Applications
- ✓Cold rooms and chillers: control mould on walls and products
- ✓Food processing: conveyors, packing areas and hoods
- ✓Clinics, labs and cleanrooms: room and bench disinfection after hours
- ✓Cabinets and enclosures: tools, utensils and PPE
- ✓Changing rooms, washrooms and waste areas
Frequently Asked Questions
Which lamp type should I choose?
High output gives the most UV-C for large or cold areas. Instant start suits fixtures that switch on and off often. Cold cathode lamps last longest and work well in cold rooms.
Can UV-C fixtures run while people are in the room?
Not when the lamps are exposed. Run them after hours with a timer, door switch or motion sensor, or use shielded and upper-room fixtures for occupied rooms.
Do UV-C fixtures work in cold rooms?
Yes. UV-C is widely used in chillers and cold rooms to control mould. Ask us for the best lamp type for your temperature.